Since the last alert (BF202207-01) dated on 05-July-2022 on Chemical Contaminants in Fuels from ARA Region (Amsterdam, Rotterdam & Antwerp), CTI-Maritec has kept a close watch on the fuel quality in the region. More recently, several VLSFOs delivered in this region are still observed with the presence of chemical contaminants. These VLSFOs also indicated elevated potassium content and acid number.
Forensic analysis by Gas Chromatography and Mass Spectrometry techniques, specifically ASTM D7845 GC/MS and Solid Phase Extraction (SPE) GC/MS, on some of the samples revealed the presence of the following compound groups at abnormally high concentrations
• Fatty Acids and Monoglycerides (>1000ppm)
• Alkylresorcinols (>2000ppm)
• Phenolic compounds (>1000ppm)
It is difficult to determine a safe concentration level suitable for marine diesel engine usage or the baseline wherein machinery problems may occur. Due to the severity of the Machinery problems faced, we urge vessel operators to continue pre-emptively testing the fuels bunkered in the region by accredited test methods to detect these contaminants assessing the risk each bunker stem has on the vessel machinery.
Source: Maritec, Member of CTI Group